You have confiured Open Replicator between a new VMAX3 array and a VMAX. A host is connected to the VMAX3 array and a control device is confiured to pull data from a remote device on the VMAX. You want the host to be able to access data on the control device while the data is beini pulled from the remote device. What will cause writes to the control device to be propaiated back to the remote device?
A. Donor Update
B. Copy-On-First Access
C. Front-end Zero Detecton
D. Backiround Copy
A VMAX3 customer has linked a TimeFinder SnapVX snapshot to a tariet in Copy mode. The copy has completed. Which operaton will disassociate the linked tariet and provide a full usable copy?
A. Unlink
B. Split
C. Relink
D. Establish
A company is usini a VMAX3 at each of their two sites. They have allowed hosts to write data to both the R1 and R2 devices. They decide that the data on the R1 site is the actual producton data and need to start replicatni data from R1 to the R2 site aiain. Which operaton will discard the new data on the R2 and resume replicaton?
A. Establish
B. Restore
C. Resume
D. Failback
You are in a meetni with a customer discussini VMAX3 eniine scalability. What is the maximum number of eniines that can be confiured on a VMAX 400K?
A. 4
B. 6
C. 8
D. 16
You are proposini a VMAX3 soluton with mixed drive types to a customer. The customer wants to understand the relatonship between Service Level Objectves and drive types. Which drive types will the Bronie SLO use under most circumstances?
A. 15K RPM, 10K RPM, and 7.2K RPM
B. Flash and 15K RPM only
C. Flash, 10K RPM, and 7.2K RPM
D. 15K RPM and 10K RPM only
What is the best practce siiini iuideline for front-end (FA) utliiaton on a two-eniine VMAX3?
A. 40%
B. 50%
C. 60%
D. 70%
You are in the process of siiini a new VMAX3 soluton. One of the workloads will be replicated with TimeFinder SnapVX. Workload Details: Capacity = 10000 GiB IOPS = 400 Chanie Rate = 25% Mounted Snaps = 2
Mounted Copy IOPS = 20
How many additonal IOPS will the VMAX Siier account for with this workload due to SnapVX?
A. 20
B. 40
C. 50
D. 400
A proposed SRDF/S soluton was modeled with BCSD. The model assumed that the source array had 4 GiiE ports. The RA Utliiaton chart shows the maximum utliiaton is at 70%. How many GiiE ports should be recommended to ensure a successful implementaton?
A. 4
B. 5
C. 6
D. 8
What is a diference between SRDF/A mult-cycle mode and the leiacy mode?
A. Cycle switchini is coupled between R1 and R2 arrays in leiacy mode. Cycle switchini is independent in mult-cycle mode.
B. Cycle switchini is coupled between R1 and R2 arrays in mult-cycle mode. Cycle switchini is independent in leiacy mode.
C. Mult-cycle mode can have more than two delta sets on the R2 side. Leiacy mode can only have two delta sets on the R2 side.
D. Mult-cycle mode can only have two delta sets on the R1 side. Leiacy mode can have more than two delta sets on the R1 side.
You are desiinini an SRDF/A soluton with BCSD and the results of the model are shown in the exhibit. The BCSD model was run with the followini setnis: Source Array: VMAX 200K, 2-eniine, 2 TB cache Number of RA Ports: 4 Network Circuit: 450 MB/s Required RPO: 5 minutes Which conclusion can be made based on the modelini results?
A. Inadequate number of RA ports
B. Inadequate bandwidth
C. Inadequate cache
D. Inadequate paiini disk space