An engineer is troubleshooting a VRTX with the following configuration:
-Dual Shared PERC Internal cards in a fault tolerant configuration
-Nodes installed in SLOTS 1 and 2
-Virtual adapters set to Multiple Assignment
-
Two virtual drives set to Full Access on SLOTS 1 and 2
The OS of the node in SLOT 1 shows more than the two disks assigned to it.
What should the engineer do to fix this issue?
A.
Power cycle the node in SLOT 1 to reset the connections
B.
Configure MPIO services in the OS of SLOT 1
C.
Set the virtual drives to No Access on SLOT 2
D.
Set the virtual adapters to SingleAssignment
Refer to the exhibit.
An engineer sets up FCoE boot on their server. The server fails during post.
What needs to be added to the NIC settings/option ROM to make booting successful?
A. The WWN of the FIP snooping bridge
B. The WWN of the storage target
C. The WWN of the FC port ID
D. The WWN of the fibre channel switch
An engineer deploys an FX2 and plugs cables from GB1 and STK/GB2 into the management network switch for path and NIC redundancy. When the chassis is powered up, the management network is adversely affected.
What should the engineer do to fix this issue?
A. Plug the CMC Redundancy Dongle into GB1 and STK/GB2
B. Configure a separate IP address for GB2
C. Turn off STP on the management network switch
D. Change the Management Port 2 setting toRedundant
An engineer is installing two PCIe NICs into an existing VRTX chassis. Node 1 has three PCIe cards assigned to it already. After installation, the engineer is unable to assign the two new NICs to node 1.
What should the engineer do to assign the two PCIe NICs to node 1?
A. Update the CMC firmware
B. Power off the node
C. Upgrade the license
D. Reseat the NICs
An engineer responsible for server lifecycle management (e.g. Monitor, Update, Deploy) needs to build a monitoring strategy for a multi-vendor data center. The company has an established third party software as the monitoring and help desk system.
Which option should be used to integrate Dell Server hardware into this monitoring architecture?
A. Configure all Dell iDRACs to send alerts to the third party console. Use OME to do the rest of the lifecycle management.
B. Configure all Dell iDRACs to send alerts to the third party console. Use iDRAC to perform update and deployment.
C. Configure all Dell iDRACs to send alerts to OME to filter out wanted alerts and forward to the third party console. Build script to do the rest of the Dell server lifecycle management.
D. Configure all Dell iDRACs to send alerts to OME tofilter out wanted alerts and forward to the third party console. Use OME to do lifecycle management of Dell servers in the environment.
An engineer is performing system updates on a large number of systems using OpenManage Essentials. The engineer has been instructed NOT to update network adapter firmware at this time.
How can the engineer exclude a firmware update while still using the Dell Online Catalog source?
A. Delete the firmware update from the local catalog.
B. Disable the firmware update in the catalog view.
C. Filter updates by component to exclude the firmware update.
D. Create a catalog policy to exclude the firmware update.
An engineer has been given a new chassis and needs to configure the iDRACs on all servers prior to deploying an OS on them. The iDRACs need to be configured with IP addresses and a new root password.
What is the most efficient method to perform this task?
A. Use CMC QuickDeploy
B. Use iDRAC QuickLaunch
C. Use CMC Server Profiles
D. Use racadm quickdeploy
An engineer needs to enable automated proactive support from Dell for ProSupport entitled assets discovered in OpenManage Essentials.
What additional software should the engineer install?
A. Dell ProSupport for Servers
B. Dell SupportAssist for Servers
C. Dell Phone Home for OpenManage Essentials
D. Dell SupportAssist for OpenManage Essentials
A VRTX has storage set up as a RAID 10 in a 16-drive disk group. Each drive is 1.6 TB for a total of 12.8 TB space in the disk group. There are currently 14 virtual disks of 600GB each. The engineer needs to create three more virtual disks. The engineer successfully creates two virtual disks but is unable to create the third because there are NO physical disks to choose from.
What must the engineer do to create the final virtual disk?
A. Perform a reconstruct ofthe physical disk group
B. Update the Shared PERC 8 Firmware
C. Create a new disk group with additional physical disks
D. Recreate the virtual disks with 400GB allocated
An engineer is in front of an FX2 chassis and notices the I/O indicator on the left ear of the chassis is flashing amber.
What are two possible causes? (Choose two.)
A. A network link has failed for one of the add-in PCIe NICs.
B. There is a problem with the chassis PCIe infrastructure.
C. A hard drive in one of the storage sleds has failed.
D. A USB key plugged into the front of the chassis has failed.