Which set of interface types support hardware compression on VMAX 40K?
A. 10 GigE and FC
B. FC and FCoE
C. FCoE and 10 GigE
D. 1 GigE and FCoE
In a Symmetrix VMAX 40K, which engine is connected to the upper half of Direct Connect Storage bay 1D?
A. 8
B. 7
C. 1
D. 2
Which action needs to be taken if the Backend Cabling Verification fails after a Data Center relocation?
A. Contact PSE Lab for assistance.
B. Relocate the cables shown as faulted.
C. Replace the cables shown as faulted.
D. Power down and re-start the Backend Cabling Verification script.
While running the Backend Cabling Verification script, the LEDs do not match the SymmWin graphic. It halts with a message that there is a cabling error and advises moving cables. Which service engagement would require PSE intervention prior to moving the cables?
A. Data center move
B. Installation
C. DAE addition
D. Storage bay addition
A CE is dispatched to perform an FCO replacing multiple SPS. After logging into a Symmetrix VMAX 40K
running Enginuity 5876.159.102 Simplified SymmWin is automatically launched.
How should the CE proceed?
A. Close Simplified SymmWin and select SymmWin from the desktop, then select Procedure Wizard
B. Close Simplified SymmWin and select SymmWin from the desktop, then select Replace Bad FRU
C. Log off then log on using a Break Fix Credential
D. Simplified SymmWin does not support VMAX 40K
A SIB replacement is required on VMAX. The customer asks what the impact will be on the front-end ports. What should your response be?
A. VMAX 40K all front-end ports will remain online. VMAX 20K, VMAX 10K front-end ports will go offline
B. VMAX 40K, VMAX 20K all front-end ports will remain online. VMAX 10K front-end ports will go offline
C. VMAX 40K, VMAX 20K and VMAX 10K all front-end ports will remain online
D. VMAX 40K, VMAX 20K and VMAX 10K front-end ports will go offline
Which procedure wizard option would you use to validate the configuration before it is loaded into the Symmetrix system?
A. Simulation Utility
B. Procedure Utility
C. Configuration Utility
D. Comparison Utility
A customer is currently running a z/OS 1.10 Mainframe Operating System and has 3390-3 and 3390-9 devices configured. They would like to increase the size of their devices. What is the largest emulation they can upgrade to?
A. 3390 A (EAV)
B. 3380-K
C. 3390-27
D. 3390-54
Which disk types can be used in a Symmetrix VMAX?
A. SATA II, Fibre Channel, SAS and Enterprise Flash Drive (EFD)
B. SAS, SCSI, Fibre Channel, and Enterprise Flash Drive (EFD)
C. SCSI, SATA II, Fibre Channel, and Enterprise Flash Drive (EFD)
D. SAS, Fibre Channel, SCSI and SATA II (SSD)
Refer to the Exhibit.
You are implementing ESRS. Into which Ethernet port do you plug the IP cable?
A. 8
B. 7
C. 6
D. 5