A vSAN administrator has a vSAN cluster that is using vSphere Lifecycle Manager (vLCM) to manage hypervisor, server drivers, and firmware. All hosts in the cluster are compliant according to the vLCM image.
A 10GB NIC on the servers is experiencing issues, and the vSAN administrator determines a new network driver will resolve the problem. Unfortunately, the required NIC driver is a newer version compared to the driver provided by the most recent Vendor Add-on.
Which action should the vSAN administrator take to ensure the latest network driver is installed on the NIC before remediation?
A. Make sure the vLCM image is configured to use the most recent version of the Vendor Add-on
B. Add an individual component to the vLCM image that has the updated NIC driver
C. Remove theVendor Add-on from the vLCM image, and then manually install the network driver on the servers
D. Modify the vLCM image to omit the NIC Driver, and then manually update the servers with the required NIC driver
A vSAN administrator receives a request from the application team to create a virtual machine on a vSAN datastore. The requirements state that the virtual machine needs to be available quickly after a failure occurs. The solution must minimize administrative effort.
Which vSphere feature should the vSAN administrator implement?
A. Distributed Services Engine
B. vSphere High Availability
C. Fault Tolerance
D. vSphere Distributed Resource Scheduler
An administrator has successfully deployed a vSAN Stretched Cluster and needs to ensure that any virtual machines that are created are placed in the appropriate site.
Which two steps are needed to complete this task? (Choose two.)
A. Create VM/Host groups for the two sites
B. Create a single VM/Host group across both sites
C. Put the VMs in a vSphere DRS group
D. Put the VMs in the correct VM group
E. Create a storage policy that includes site affinity rules and apply to VMs
An organization wants to implement a virtual desktop infrastructure (VDI) solution on their vSAN storage. They also need to store their applications running inside the VDI environment on vSAN storage. Which two end-user computing (EUC) solutions could be implemented to satisfy the requirements of the organization? (Choose two.)
A. Agp_ Volumes
B. Workspace ONE Access
C. Horizon
D. Workspace ONE UEM
E. Dynamic Environment Manager
An all-flash vSAN ESA cluster contains four nodes.
Which two storage policies can the cluster satisfy? (Choose two.)
A. FTT=3 (RAID-1 Mirroring)
B. FTT=2 (RAID-1 Mirroring)
C. FTT=I (RAID-5 Erasure Coding)
D. FTT=I (RAID-1 Mirroring)
E. FTT=2 (RAID-6 Erasure Coding)
After a planned power outage, an administrator decided to restart the vSAN cluster manually.
What is the correct sequence of steps for the administrator to follow after powering on the ESXi hosts?
A. 1. Enable cluster member updates from vCenter Server only on one ESXi host.
2.
Run the python reboot helper script only on one ESXi host to recover the cluster.
3.
Exit all hosts from maintenance mode.
B. 1. Exit all hosts from maintenance mode.
2.
Run the python reboot helper script only on one ESXi host to recover the cluster.
3.
Enable cluster member updates from vCenter Server on all ESXi hosts.
C. 1. Exit all hosts from maintenance mode.
2.
Enable cluster member updates from vCenter Server only on one ESXi host.
3.
Run the python reboot helper script only on one ESXi host to recover the cluster.
D. 1. Enable cluster member updates from vCenter Server on all ESXi hosts.
2.
Run the python reboot helper script on all ESXi hosts to recover the cluster.
3.
Exit all hosts from maintenance mode.
A site administrator wishes to implement HCI mesh between two clusters on vSAN that are located in geographically separate sites and which are administered within a single datacenter.
Which two requirements should the vSAN administrator consider to accomplish this goal? (Choose two.)
A. Either Layer 2 or Layer 3 communications can be used
B. A leaf spine topology is required for core redundancy and reduced latency
C. NIC teaming must be implemented for the vSAN network vmkernel port
D. The configuration must meet the same latency and bandwidth requirement as local vSAN
E. Encryption must be disabled prior to configuring HCI mesh
What are two characteristics of a durability component in vSAN? (Choose two.)
A. Better Performance
B. Faster resynchronization
C. Faster snapshot creation
D. Better Storage utilization
E. Better Availability
Which VMware solution requires vSAN usage?
A. VMware Cloud Foundation
B. VMware Horizon
C. VMware Telco Cloud Automation
D. VMware Aria Automation
A vSAN administrator has two identical VMware vSAN clusters, one for staging workloads and another for production workloads. Due to an unforeseen capacity requirement, the vSAN administrator is tasked with merging the staging vSAN cluster into the production.
Which three actions should the vSAN administrator perform on the staging cluster prior to moving the vSAN nodes to the production cluster? (Choose three.)
A. Disable vSAN Services
B. Delete all Disk Groups
C. Enable File Services
D. Delete all partitions from the capacity disks
E. Mark the disks for partial reservation
F. Remove all capacity drives